Oxidizers - Thermal & Catalytic

Gas Fired Thermal Oxidizers are typically used for destruction of higher concentrations of VOCs. When operated in a straight thermal mode, the units are fired to 1400° F and retention times are 1.5 seconds. Destruction is typically >99.99% for VOCs. When operated in catalytic mode, the units are fired to 700° F and destruction is typically >99%.

Thermal Catalytic Oxidizer

Features

  • Skid or Trailer Mounted
  • Carbon Steel Combustion Chamber
  • 6” Refractory Lining on Shell
  • Inlet Flame Arrestor
  • Hauk Process Burner and Combustion Fan
  • NFPA and AGA Approved Gas Train
  • 3rd Party NRTL Listed Control Panel
  • 230 VAC or 480 VAC
  • Stainless Steel Type K Thermocouples
  • Purge/Dilution Actuated Butterfly Valve
  • Pressure Switch to Monitor Inlet Process Flow
  • ABB High Visibility Temp Controllers with Retransmission Feature
  • Siemens Logo PLC with Touch Screen for Control and Trending Functionality
  • System Pre-Tested Prior to Shipment

Available Options & Services

  • Process Blower VFD for Precise Operation
  • Wireless Telemetry for Remote Monitoring
  • Catalytic Conversion Modules with Integrated Heat Recovery
  • Alloy Construction for Chlorinated Solvent Vapor Processing
  • Wet Scrubber Packages for Chlorinated Solvent Recovery Off-Gas Processing
  • Custom Integration Into New or Existing Systems
  • Installation, Integration, and Operations Services
Gas Oxidizer

Description

PRM uses a unique 90 degree burner tube and we crossfire the inlet fume directly into the most intent flame of the burner. Cross firing is done where there is no potential for creation of erratic flame. Cross firing of the fume into the burner provides destruction that other oxidizers do not obtain.

PRM Gas Fired Thermal Oxidizers are the safest oxidizers on the market. We go to additional steps to ensure safety. These safety steps are invisible to the operator as the PLC controller is providing background scans continuously, looking for potential problems.

With NFPA 86, the maximum loading allowable of VOCs in an oxidizer is 25% of the LEL. With CEM equipment, the allowance is up to 50% loading.