Flare Systems
Utility and enclosed flare designs from 50 to 10,000 SCFM. Custom designed and manufactured in-house with proprietary pilot burner technology for reliable methane destruction up to 99% efficiency.
Methane & CO₂ Control for Landfill Applications
PRM Flare Systems are used for controlling methane (CH₄) and carbon dioxide (CO₂), byproducts of landfill biodegradation. We specialize in designing and manufacturing flares for landfill applications up to 10,000 SCFM with destruction rates of up to 98% efficiency for utility flares and greater than 99% for enclosed designs.
Additional markets include wastewater and agricultural applications. Landfills that utilize gas for energy production require a contingency flare to destroy excess gas when co-generation equipment is offline.
View Rental Flare InventoryFeatures
- Complete in-house design and manufactured for compliant operation
- Skid mounted for easy, low-cost installation
- Proprietary pilot burner ensures complete gas destruction
- 10:1 or greater turndown ratio
- Candlestick or enclosed flares up to 10,000 CFM
- Combustion systems comply with NFPA 86
- Windshield design improves operational stability and turndown
- Adjustable thermocouples for temperature control
Flare System Options
PRM manufactures both utility and enclosed flare designs, plus rental systems for pilot testing before permanent installation
Utility / Candlestick Flares
The candlestick flare combusts excess landfill or biogas (40–55% methane) by discharging through a pipe and windshield. Monitored by thermocouple or UV scanner, achieving efficiencies greater than 98%.
- 50–10,000 CFM capacity range
- Meets EPA 40CFR 60.18 destruction efficiency
- Designed per AP-42 standards
Best for: Municipal landfills, solid waste facilities
Enclosed Flares
Combusts gases inside a vertical, insulation-lined chamber for increased destruction efficiency (>99%). Allows sampling to confirm destruction for carbon credit optimization. Concealed flame is aesthetically appealing.
- Greater than 99% destruction efficiency
- Sampling ports confirm destruction rates
- Optional staged burners for NOx compliance
Best for: Carbon credit sites, aesthetically sensitive locations
Rental Flare Systems
PRM has flare skid systems available for short or long-term rental. A rental system allows a pilot test to establish the flow capacity of the landfill before committing to a permanent installation.
- Complete system: blower skid, knockout tank, controls
- Short or long-term lease terms available
- 100+ rental systems currently deployed nationwide
Proprietary Burner & Pilot Design
PRM manufactures a proprietary pilot and burner design to provide reliable flame stability during a variety of weather and gas conditions. Our pilot and burner assemblies are constructed of heavy-gauge stainless steel to improve system life. Sustained combustion is typical without a pilot, but the pilot is available to actuate as needed, ensuring uninterrupted gas destruction.
Compliance Standards
- NFPA 86 combustion system compliance
- EPA 40CFR 60.18 destruction efficiency
- AP-42 standards compliance
- Class 1 Div 2 hazardous location wiring
System Integration
- Siemens SIMATIC PLC control systems
- SCADA with remote monitoring and telemetry
- Gas extraction blower skid integration
- Contingency flare for gas-to-energy systems
Example Projects
Successful flare installations across North America, from portable biogas flares to multi-megawatt enclosed systems
Vancouver, BC
Enclosed flare system on 8' × 20' channel frame skid. 40' tall enclosed LFG flare with carbon steel moisture separator. Gas routed through three generator packages for >5MW grid output. Siloxane/H₂S control system included.
Cortland, NY
Flare blower system with PRM moisture separators, Continental multistage centrifugal blowers, Siemens SIMATIC S7-1200 PLC, HMI Comfort Panels, Yaskawa GA500 VFD, and Cradlepoint cellular telemetry.
Lubbock, TX
12' diameter, 30' high candlestick flare on a 10' × 20' steel-framed skid. 30 HP Continental multistage blower (MS400) with MS tank. Designed for 2,000 SCFM flow rate.
Page County, VA
500 CFM biogas flare with 10:1 turndown. Skid-mounted with hinged design for raising/lowering. UL-listed Siemens S1200 PLC, 10 HP Gast regenerative blower with VFD. Class 1 Div 2 wiring.
Petersburg, VA
500 CFM biogas flare with 10:1 turndown. Portable hinged skid design. UL-listed Siemens S1200 PLC, 7.5 HP Eurus blower with VFD. Class 1 Div 2 hazardous location wiring.
Wake County, NC
Candlestick flare and gas extraction system for municipal landfill gas destruction.
Related Products
Complete your gas destruction system with complementary equipment

Gas Extraction Blowers
Complete extraction systems that create negative pressure in well fields to transfer gas to flare stations.
Learn More
Gas Flow Instrumentation
Fixed and portable gas analyzers for greenhouse gas destruction verification and carbon credit calculations.
Learn More
Control Panels & SCADA
UL-listed panels with integrated SCADA for automated flare system monitoring and control.
Learn MoreReady to Discuss Your Flare System?
From pilot testing with rental flares to permanent utility and enclosed installations, our team can help you select the right flare system for your site requirements.